    Power equipment
    Reactor
    High Voltage static dynamic reactive Power compensation and filter device
    TBB High voltage automatic reactive power compensation unit
    High and low voltage electrical equipment
    Voltage transformer
    Other type Power equipment
    Electrical components
    Indoor high voltage electrical components
    Outdoor high voltage AC vacuum circuit breaker
    Voltage and current transformer
    Electrical condenser
    Lightning protector
    Other electrical components
    Other products

    Imported products

    Hotline

    86-(0)577-62262979

    High Voltage static dynamic reactive Power compensation and filter device

    MEC module of power quality integrated optimization device

    MEC module product introduction
    The MEC module for comprehensive optimization of new power power power quality has a fast dynamic reactive power compensation, which can be used to compensate for impact loads by transforming the variable capacitive reactive power into rated reactive power in a very short period of time. There will be no problems such as overfilling or underfilling, and the filtering of the high harmonics of each phase will effectively control the voltage fluctuations and flash changes of the grid, suppress the imbalance of the three-phase(current) of the grid, and dampen the resonance of the grid, which is suitable for various working conditions. It is beyond the reach of traditional reactive compensation equipment.
    Comparison of MEC Module with TSC + APF Technology and SVG + APF Technology
    product
    New Power MEC Module
    TSC+APF
    Other SVG + APF
    Reactive power compensation capacity
    Gradless adjustment from capacity to rated sensibility, good compensation effect
    Graded casting and cutting adjustment, there are cases of overpayment and underpayment, the compensation effect is poor
    Gradless adjustment from capacity to rated sensibility, good compensation effect
    Compensatory capacity
    Module nominal capacity is the rated output capacity of the device, the selection of simple
    The actual output capacity of the module is less than the nominal capacity of the capacitor. It is necessary to use the formula to convert it. The selection type is relatively complex.
    Module nominal capacity is the rated output capacity of the device, the selection of simple
    Full Response Time
    Full response time is fast, ≤ 3ms
    Full response time is longer, ≥ 30ms
    Full response time is fast, ≤ 3ms
    Three-phase imbalance management
    Three-phase AC power through the DC side connection, can deploy power, three-phase imbalance management ability is strong
    No such function
    Three-phase AC power through the DC side connection, can deploy power, three-phase imbalance management ability is strong
    reliability
    Module unit in parallel, backup each other, fault unit does not affect the operation of the entire machine, high reliability
    Self-healing capacitor is easy to resonate with the system after the capacity attenuation, damaging the equipment in the system, and the reliability is poor.
    Two sets of control systems are installed on the same bus. There may be interference and low reliability
    Environmental adaptation
    Power module seal, independent duct, no need for regular circuit maintenance, significantly reduce dust caused failure
    All the parts are open structure, operation is easily affected by dust, failure
    All the parts are open structure, operation is easily affected by dust, failure
    Useful life
    Imported electric electronic components IGBT, no vulnerable parts, design service life greater than 20 years
    The capacity value of self-healing capacitor decays rapidly during use, and the general service life is 2 to 4 years.
    Imported electric electronic components IGBT, no vulnerable parts, design service life greater than 20 years
    Installation Size
    Modular design, high power density, small area
    Compensation and filtering are installed in two cabinets, covering a large area
    Compensation and filtering are installed in two cabinets, covering a large area
    Investment in equipment
    Reactive power harmonic wave management capacity vector superposition, the total equipment capacity is relatively low, the total equipment investment is low
    The total capacity of reactive power harmonic wave management capacity is relatively large and the equipment investment is higher
    The total capacity of reactive power harmonic wave management capacity is relatively large and the equipment investment is the highest
    Features of the MEC module
    MEC module, single capacity 30 ~ 150 kvar
    Simple interface, easy connection and parallel connection
    Compensation of reactive power, harmonic, three-phase imbalance, shock, voltage flash
    Unique corrugated self-elimination technology
    Set SVG and APF functions as one, low cost
    It has low power consumption and small land area.
    Independent wind tunnel design, free of maintenance

    Description

    SVG module technical parameters

    specifications
    NPVM04-30

    NPVM04-50

    NPVM04-75

    NPVM04-100

    NPVM04-150

    Rated voltage(VAC)
    400
    Input Voltage Range(VAC)
    400(-20%~+15%)
    Rated capacity(kvar
    ±30

    ±50

    ±75

    ±100

    ±150

    Frequency of operation(Hz)
    50±5%
    rated current(A)
    43

    72

    108

    144

    217

    Overload current multiples
    1.1
    Shape Size/mm(WxDxH
    177x380x565

    234x380x595

    225x530x580

    225x535x1280

    Line system
    Three-phase three-wire / three-phase four-wire
    Working Environment Temperature(℃)
    -25~+45℃(40℃以上Need to reduce the amount used)
    Operating environmental humidity(%)
    <95%,No condensation.
    Cooling mode
    Forced air cooling
    Protection Level
    IP21
    Harmonic
    Meet the Harmonics of Public Power Quality Grid GB/T14549-93
    Work elevation
    0~3000m(>2000m,100 m per rise,1 per cent reduction)
    Reactive power regulation range
    Continuous adjustable from capacitive reactive power to rated reactive power
    The number of harmonics that can be filtered
    2~13
    Harmonic compensation rate
    >80%
    Response time
    ≤3ms
    Allow voltage surge
    110%
    Allow voltage drop
    50%
    Allow voltage flicker width
    2S
    Three-phase voltage imbalance
    Normal rated power ± 2 %, short time rated power ± 5 %
    display
    7Inch LCD Screen/8Inch Graphics TFTTrue color display(optional)
    Smart Communications
    Modbus、Bluetooth(optional), GPRS(optional)、TCP/IP(optional)
    Reliability and life span
    Design life 20 years
    Electromagnetic compatibility
    Compliance GB7251-2005(GB/T 7261-2000
    Send Inquiry

    Please feel free to contact with us at sales@cnshengyuan.cn, info@cnshengyuan.cn or filling up an enquiry form instructed at the bottom, You will get an effective response within 24 hours from Shengyuan sales representative.
    Thanks for your valued time with interest!

    • Subject:
    • *Name:
    • *E-mail:
    • Company Name:
    • Tel:
    • Fax:
    • Country:
    • Message:

    Related Products

    • PV inverter

    • Wind power full power converter

    • Three-phase load regulator(TLB)

    • Grid Special Chain Static Reactive Power Generator(SVG)

    • Integrated Optimization Device(MEC) for Distribution Network

    • Integrated Optimization Device for Special Power Quality(MEC)

    • Integrated Optimization Device for Special Power Quality(MEC)

    • Advanced Uninterruptible Power Supply(AUPS)

    • Dynamic Reactive Power Generator(TSVG)

    • Dynamic Voltage Restorer(NVR)

    • Silicon Controlled Dynamic Reactive Power Compensation Device(TSC)

    • Parallel Static Reactive Power Generator(SVG)

    • Active Filter APF Module

    • Active Filter(APF)

    • Electrical Power Quality Integrated Optimization Device MEC

    • SVG module for static reactive power generator

    • High Pressure Chain Static Reactive Power Generator(SVG)

  • <blockquote id="4o8gq"><label id="4o8gq"></label></blockquote>
  • <menu id="4o8gq"><tt id="4o8gq"></tt></menu>
  • qq棋牌