Online Service
Product |
Multifunctional electricity controller & optimizer (MEC) |
Mechanical switch capacitor (MSC) |
Thyristor-switched capacitor (TSC) |
Response speed |
≤2ms |
300ms |
20ms |
Reactive power compensation ability |
Rated capacitive reactive power to rated inductive reactive power, 0.1kVar precision, and up to 1 power factor |
0 to rated capacitive reactive power, stair-like adjustment, transient and possible over-compensation and under-compensation, with the average power factor up to standard |
0 to rated capacitive reactive power, stair-like adjustment, transient and easy for over-compensation and under-compensation, with the average power factor up to standard |
Harmonic control ability |
Filter out harmonics for 2-13 times, filtering rate over 80%, no resonance oscillation risks |
No harmonic-filtering ability, large harmonics amplification and resonance risks |
No harmonic-filtering ability, large harmonics amplification and resonance risks |
Three-phase imbalance contro |
Strong, adjustable three-phase active power |
None |
None |
Voltage stabilization ability |
Strong, output capacity not change along with the drop of voltage, fast response to voltage leap |
Worse, the output capacity decreases by squares when the voltage decreases, resulting in system voltage fluctuation during switching |
Worse, the output capacity decreases by squares when the voltage decreases, resulting in system voltage fluctuation during switching |
Anti-electricity dazzling ability |
Possess the ability of preventing electricity dazzling from +10% to -50% |
None |
None |
Reliability |
Without capacitance wearing parts, and failure-free operating time of 100,000 hours |
With the switch-on rush current, over-voltage and resonance phenomena, the contactor is vulnerable to contact welding, and the capacitor is vulnerable to damages due to harmonics, with a high fault rate |
With the switch-on rush current, over-voltage and resonance phenomena, and the capacitor is vulnerable to damages due to harmonics, with a high fault rate |
Service life |
Design life over 20 years |
Capacitance attenuation, service life of 2-3 years |
Capacitance attenuation, service life of 2-3 years |
Maintenance cost |
Low, maintenance-free |
High, the capacitor should be replaced annually at later stage |
High, the capacitor should be replaced annually at later stage |
Impacts on the service life of transformer |
Power compensation, harmonic filtering, adjustment of three-phase balance, reducing the load rate and temperature rise of transformer, and increasing the service life of transformer by 50% |
Only compensating the reactive power, and impossible for eliminating the major damages on transformer caused by harmonics and three-phase imbalance, resulting in high load rate and short service life of transformer. The transformer may be burnt up due to resonance |
Only compensating the reactive power, and impossible for eliminating the major damages on transformer caused by harmonics and three-phase imbalance, resulting in high load rate and short service life of transformer. The transformer may be burnt up due to resonance |
Remote monitoring |
With the Bluetooth+GPRS monitoring function, available for networking remote management |
None |
None |
?Features |
|
?Application fields |
1. 200V, 400V, 600V, and 750V, and unit capacity up to 10Mvar;
2. Simultaneous compensation of reactive power, harmonic, three-phase imbalance, electricity-dazzling; 3. Modular parallel design, the module failure imposes no impacts on the operation of other modules, available for live replacement what gives high reliability; 4. Integrate functions of SVG and APF into one, low cost; 5. Adopt the PWM interleaving technique, with low harmonic of itself; 6. Small land occupation area, and the design life up to 20 years. |
1. Power system in need of comprehensive compensation against reactive power, harmonic and three-phase imbalance.
2. Power system sensitive to the voltage fluctuation and flickering of power network, such as that related to precise textile. 3. High voltage and ultra-high voltage flexible AC power transmission. 4. Compensation to large industrial consumers such as steel metallurgical enterprises and petrochemical engineering enterprise. 5. The remote and border areas with poor electricity availability, such as the rural areas, mountainous areas, and wind power plant. 6. Special compensation to large loads such as the rolling mill, electric-arc furnace, electrified rail traction power station, etc. |
Please feel free to contact with us at sales@cnshengyuan.cn, info@cnshengyuan.cn or filling up an enquiry form instructed at the bottom, You will get an effective response within 24 hours from Shengyuan sales representative.
Thanks for your valued time with interest!
PV inverter
Wind power full power converter
Three-phase load regulator(TLB)
Grid Special Chain Static Reactive Power Generator(SVG)
Integrated Optimization Device(MEC) for Distribution Network
Integrated Optimization Device for Special Power Quality(MEC)
Integrated Optimization Device for Special Power Quality(MEC)
Advanced Uninterruptible Power Supply(AUPS)
Dynamic Reactive Power Generator(TSVG)
Dynamic Voltage Restorer(NVR)
Silicon Controlled Dynamic Reactive Power Compensation Device(TSC)
Parallel Static Reactive Power Generator(SVG)
Active Filter APF Module
Active Filter(APF)
MEC module of power quality integrated optimization device
SVG module for static reactive power generator
High Pressure Chain Static Reactive Power Generator(SVG)